@@ -100,17 +100,21 @@ SENSOR_KEYS = [
|
|
|
# `scale` converts the source value into the unit declared in
|
|
|
# SENSOR_DEFINITIONS.
|
|
|
#
|
|
|
-# Units for the per-field values below are taken from the sample payload in
|
|
|
-# issue #7 (bmsBatteryVoltage 26.6 V, batteryPercentage 100 %, batteryPower 9 W,
|
|
|
-# positiveTerminalBatteryCurrent 0.4 A, pv1Power/pv2Power in W). The kW→W
|
|
|
-# scaling for the aggregate flow values (generationPower, load_power) matches
|
|
|
-# both the reporter's own reading of the portal and the pre-existing kW→W
|
|
|
-# normalisation this integration already applies to acOutputActivePower on the
|
|
|
-# time-series path — i.e. this portal reports aggregate power in kW.
|
|
|
+# ONLY mappings whose unit is confirmed by a NON-ZERO observed value are enabled
|
|
|
+# here. Every rule below has scale 1.0 — the value is published exactly as the
|
|
|
+# portal reports it — so no rule in this table can be 1000x wrong. The issue #7
|
|
|
+# payload was captured at night, so it pinned down the units of only these
|
|
|
+# fields:
|
|
|
+# bmsBatteryVoltage / positiveTerminalBatteryVoltage 26.6 V
|
|
|
+# batteryPercentage / bmsSOC 100 %
|
|
|
+# batteryPower 9 W
|
|
|
+# pv1Power / pv2Power W (labelled; 0 at night)
|
|
|
+# Anything that would need a kW→W conversion, or whose direction/sign is
|
|
|
+# ambiguous, is listed in ENERGY_FLOW_UNVERIFIED below and left unmapped until a
|
|
|
+# daytime, under-load capture confirms it.
|
|
|
ENERGY_FLOW_RULES: dict[str, list[tuple[str, tuple[str, ...], float]]] = {
|
|
|
"pvInputPower": [
|
|
|
("sum", ("pv1Power", "pv2Power", "pv3Power", "pv4Power"), 1.0),
|
|
|
- ("first", ("generationPower",), 1000.0),
|
|
|
],
|
|
|
"batteryVoltage": [
|
|
|
("first", ("bmsBatteryVoltage", "positiveTerminalBatteryVoltage"), 1.0),
|
|
|
@@ -121,30 +125,38 @@ ENERGY_FLOW_RULES: dict[str, list[tuple[str, tuple[str, ...], float]]] = {
|
|
|
"batteryPower": [
|
|
|
("first", ("batteryPower",), 1.0),
|
|
|
],
|
|
|
- "batteryDischargeCurrent": [
|
|
|
- ("first", ("positiveTerminalBatteryCurrent",), 1.0),
|
|
|
- ],
|
|
|
- "batteryChargingCurrent": [
|
|
|
- ("first", ("negativeTerminalBatteryCurrent",), 1.0),
|
|
|
- ],
|
|
|
- "loadPower": [
|
|
|
- ("first", ("load_power", "loadPower"), 1000.0),
|
|
|
- ],
|
|
|
- "acOutputActivePower": [
|
|
|
- ("first", ("load_power", "loadPower"), 1000.0),
|
|
|
- ],
|
|
|
}
|
|
|
|
|
|
-# Fields observed in the issue #7 payload that are deliberately NOT mapped yet.
|
|
|
-# Every sample value the reporter captured was zero (the reading was taken at
|
|
|
-# night), so the kW-vs-W scale cannot be pinned down. Guessing wrong here would
|
|
|
-# push a value that is 1000x off into the HA Energy dashboard and long-term
|
|
|
-# statistics, which is materially worse than leaving the sensor "unknown".
|
|
|
-# Revisit once a daytime sample with non-zero values is available.
|
|
|
+# Fields observed in the issue #7 payload that are deliberately NOT mapped.
|
|
|
+# Publishing a wrong value is worse than leaving a sensor "unknown": a 1000x
|
|
|
+# scaling error feeds the HA Energy dashboard and long-term statistics, and
|
|
|
+# statistics cannot be un-poisoned by a later fix. Two distinct reasons:
|
|
|
+#
|
|
|
+# 1. UNIT UNCONFIRMED (kW vs W). Every captured sample was zero because the
|
|
|
+# reading was taken at night, so the scale cannot be pinned down. The
|
|
|
+# reporter labelled these kW, and this integration already applies kW→W to
|
|
|
+# acOutputActivePower on the time-series path, so x1000 is *probably* right —
|
|
|
+# but "probably" is not good enough for a value that lands in statistics.
|
|
|
+# 2. DIRECTION UNCONFIRMED. The battery terminal currents carry the right
|
|
|
+# magnitude (26.6 V x 0.4 A ~= 9 W, matching the reported batteryPower), but
|
|
|
+# which terminal means charge and which means discharge is unverified — the
|
|
|
+# reporter flagged it, and a swap would invert charge/discharge, which is
|
|
|
+# actively misleading rather than merely absent.
|
|
|
+#
|
|
|
+# Revisit once two captures from issue #7 are available: one in daylight under
|
|
|
+# load (settles the units), one while the battery is actively charging (settles
|
|
|
+# the direction).
|
|
|
ENERGY_FLOW_UNVERIFIED: tuple[str, ...] = (
|
|
|
+ # 1. unit unconfirmed (kW vs W)
|
|
|
"aPhaseMainsPower", # candidate for gridPower (sum of the three phases)
|
|
|
"bPhaseMainsPower",
|
|
|
"cPhaseMainsPower",
|
|
|
+ "generationPower", # candidate aggregate fallback for pvInputPower
|
|
|
+ "load_power", # candidate for loadPower / acOutputActivePower
|
|
|
+ "loadPower",
|
|
|
+ # 2. direction unconfirmed (which terminal is charge vs discharge)
|
|
|
+ "positiveTerminalBatteryCurrent",
|
|
|
+ "negativeTerminalBatteryCurrent",
|
|
|
)
|
|
|
|
|
|
# Canonical keys that indicate the time-series endpoint returned usable realtime
|