@@ -91,6 +91,9 @@ from .const import (
|
|
|
API_DEVICE_LIST,
|
|
|
API_SETTINGS_GET,
|
|
|
API_SETTINGS_SET,
|
|
|
+ API_ENERGY_FLOW,
|
|
|
+ ENERGY_FLOW_RULES,
|
|
|
+ REALTIME_PROBE_KEYS,
|
|
|
IOT_APP_ID,
|
|
|
IOT_APP_SECRET_ENC,
|
|
|
TOKEN_REFRESH_LEAD_SECONDS,
|
|
|
@@ -208,6 +211,88 @@ def _parse_expiry(value: str | None) -> datetime | None:
|
|
|
return None
|
|
|
|
|
|
|
|
|
+# ──────────────────────────────────────────────────────────────────────────────
|
|
|
+# Energy-flow fallback mapping
|
|
|
+# ──────────────────────────────────────────────────────────────────────────────
|
|
|
+
|
|
|
+def _coerce_number(value: Any) -> float | None:
|
|
|
+ """Best-effort conversion of an API field value to a float.
|
|
|
+
|
|
|
+ The energy-flow payload has only been observed second-hand (issue #7), so
|
|
|
+ accept every shape this portal is known to use elsewhere: a bare number, a
|
|
|
+ numeric string, a latest-wins list (as the time-series endpoint returns), or
|
|
|
+ a {"value": ...} wrapper. Anything unrecognised yields None so the caller
|
|
|
+ leaves the sensor untouched instead of publishing a garbage reading.
|
|
|
+ """
|
|
|
+ if value is None or isinstance(value, bool):
|
|
|
+ return None
|
|
|
+ if isinstance(value, (int, float)):
|
|
|
+ return float(value)
|
|
|
+ if isinstance(value, str):
|
|
|
+ text = value.strip()
|
|
|
+ if not text:
|
|
|
+ return None
|
|
|
+ try:
|
|
|
+ return float(text)
|
|
|
+ except ValueError:
|
|
|
+ return None
|
|
|
+ if isinstance(value, list):
|
|
|
+ for item in reversed(value):
|
|
|
+ number = _coerce_number(item)
|
|
|
+ if number is not None:
|
|
|
+ return number
|
|
|
+ return None
|
|
|
+ if isinstance(value, dict):
|
|
|
+ for key in ("value", "val", "latest"):
|
|
|
+ if key in value:
|
|
|
+ return _coerce_number(value[key])
|
|
|
+ return None
|
|
|
+
|
|
|
+
|
|
|
+def map_energy_flow_fields(fields: Any) -> dict[str, float]:
|
|
|
+ """Translate an energy-flow ``fields`` mapping into canonical sensor keys.
|
|
|
+
|
|
|
+ Pure function: no network access and no instance state, so it can be tested
|
|
|
+ directly. Applies ENERGY_FLOW_RULES in declaration order and returns only
|
|
|
+ the keys it could actually resolve — the caller merges the result without
|
|
|
+ clobbering better data from the time-series endpoint.
|
|
|
+ """
|
|
|
+ if not isinstance(fields, dict) or not fields:
|
|
|
+ return {}
|
|
|
+
|
|
|
+ mapped: dict[str, float] = {}
|
|
|
+
|
|
|
+ for canonical, rules in ENERGY_FLOW_RULES.items():
|
|
|
+ for mode, sources, scale in rules:
|
|
|
+ if mode == "sum":
|
|
|
+ values = [
|
|
|
+ number
|
|
|
+ for source in sources
|
|
|
+ if (number := _coerce_number(fields.get(source))) is not None
|
|
|
+ ]
|
|
|
+ if values:
|
|
|
+ mapped[canonical] = sum(values) * scale
|
|
|
+ else: # "first" — first present source field wins
|
|
|
+ for source in sources:
|
|
|
+ number = _coerce_number(fields.get(source))
|
|
|
+ if number is not None:
|
|
|
+ mapped[canonical] = number * scale
|
|
|
+ break
|
|
|
+ if canonical in mapped:
|
|
|
+ break
|
|
|
+
|
|
|
+ return mapped
|
|
|
+
|
|
|
+
|
|
|
+def has_realtime_values(values: Any) -> bool:
|
|
|
+ """Return True if any canonical realtime key carries a usable number."""
|
|
|
+ if not isinstance(values, dict):
|
|
|
+ return False
|
|
|
+ return any(
|
|
|
+ _coerce_number(values.get(key)) is not None for key in REALTIME_PROBE_KEYS
|
|
|
+ )
|
|
|
+
|
|
|
+
|
|
|
# ──────────────────────────────────────────────────────────────────────────────
|
|
|
# Main API client
|
|
|
# ──────────────────────────────────────────────────────────────────────────────
|
|
|
@@ -512,6 +597,28 @@ class SolarOfThingsAPI:
|
|
|
resp.raise_for_status()
|
|
|
return resp.json()
|
|
|
|
|
|
+ def _get(self, path: str, params: dict[str, Any], *, timeout: int = 30) -> dict[str, Any]:
|
|
|
+ """Perform a GET to a data endpoint, refreshing the token once on 401.
|
|
|
+
|
|
|
+ Mirrors _post's retry behaviour: on a second 401 the nested
|
|
|
+ _ensure_token_valid raises TokenExpiredError, which the coordinator
|
|
|
+ turns into a re-auth flow.
|
|
|
+ """
|
|
|
+ self._ensure_token_valid()
|
|
|
+
|
|
|
+ url = f"{API_BASE_URL}{path}"
|
|
|
+ resp = self.session.get(url, params=params, timeout=timeout)
|
|
|
+
|
|
|
+ if resp.status_code == 401:
|
|
|
+ _LOGGER.warning("SolarOfThings: received 401 on GET; forcing token refresh")
|
|
|
+ # Force an immediate refresh even if _token_needs_refresh() is False
|
|
|
+ self._access_expires = None
|
|
|
+ self._ensure_token_valid()
|
|
|
+ resp = self.session.get(url, params=params, timeout=timeout)
|
|
|
+
|
|
|
+ resp.raise_for_status()
|
|
|
+ return resp.json()
|
|
|
+
|
|
|
# ─── Public properties (for persistence in HA config entry) ───────────────
|
|
|
|
|
|
@property
|
|
|
@@ -591,7 +698,61 @@ class SolarOfThingsAPI:
|
|
|
# ─── Time-series (per device) ──────────────────────────────────────────────
|
|
|
|
|
|
def fetch_latest_data(self, device_id: str) -> dict[str, Any]:
|
|
|
- """Fetch the latest readings for a device (last 1 hour)."""
|
|
|
+ """Fetch the latest readings for a device (last 1 hour).
|
|
|
+
|
|
|
+ The historical time-series endpoint is the primary source. Several
|
|
|
+ inverter / WiFi-dongle firmware families never populate it, which leaves
|
|
|
+ every realtime entity "unknown" even though the portal shows live data
|
|
|
+ (issue #7). For those devices we fall back to the live energy-flow
|
|
|
+ endpoint and translate its field names onto the canonical sensor keys.
|
|
|
+ """
|
|
|
+ latest_values = self._fetch_time_series_values(device_id)
|
|
|
+
|
|
|
+ if not has_realtime_values(latest_values):
|
|
|
+ _LOGGER.debug(
|
|
|
+ "SolarOfThings device %s: time-series returned no realtime "
|
|
|
+ "values; trying energy-flow fallback",
|
|
|
+ device_id,
|
|
|
+ )
|
|
|
+ try:
|
|
|
+ fields = self.fetch_energy_flow(device_id)
|
|
|
+ except TokenExpiredError:
|
|
|
+ # Must reach the coordinator so it can start the re-auth flow.
|
|
|
+ raise
|
|
|
+ except Exception as err:
|
|
|
+ _LOGGER.debug(
|
|
|
+ "SolarOfThings device %s: energy-flow fallback unavailable: %s",
|
|
|
+ device_id,
|
|
|
+ err,
|
|
|
+ )
|
|
|
+ else:
|
|
|
+ mapped = map_energy_flow_fields(fields)
|
|
|
+ if mapped:
|
|
|
+ _LOGGER.debug(
|
|
|
+ "SolarOfThings device %s: energy-flow fallback resolved %s",
|
|
|
+ device_id,
|
|
|
+ sorted(mapped),
|
|
|
+ )
|
|
|
+ # Only fill gaps — never clobber a time-series reading.
|
|
|
+ for key, value in mapped.items():
|
|
|
+ latest_values.setdefault(key, value)
|
|
|
+ elif fields:
|
|
|
+ # Unknown firmware variant: surface the field names so they
|
|
|
+ # can be added to ENERGY_FLOW_RULES from a bug report.
|
|
|
+ _LOGGER.warning(
|
|
|
+ "SolarOfThings device %s: energy-flow returned %d field(s) "
|
|
|
+ "but none matched a known mapping. Please open an issue "
|
|
|
+ "with these key names: %s",
|
|
|
+ device_id,
|
|
|
+ len(fields),
|
|
|
+ sorted(fields),
|
|
|
+ )
|
|
|
+
|
|
|
+ self._apply_derived_values(latest_values)
|
|
|
+ return latest_values
|
|
|
+
|
|
|
+ def _fetch_time_series_values(self, device_id: str) -> dict[str, Any]:
|
|
|
+ """Return the latest value per key from the historical time-series API."""
|
|
|
end_time = self._now()
|
|
|
start_time = end_time - timedelta(hours=1)
|
|
|
|
|
|
@@ -634,28 +795,62 @@ class SolarOfThingsAPI:
|
|
|
|
|
|
# Unit normalisation: acOutputActivePower is kW in API → W
|
|
|
if "acOutputActivePower" in latest_values:
|
|
|
- try:
|
|
|
- latest_values["acOutputActivePower"] = (
|
|
|
- float(latest_values["acOutputActivePower"]) * 1000.0
|
|
|
- )
|
|
|
- except Exception:
|
|
|
- pass
|
|
|
+ converted = _coerce_number(latest_values["acOutputActivePower"])
|
|
|
+ if converted is not None:
|
|
|
+ latest_values["acOutputActivePower"] = converted * 1000.0
|
|
|
+
|
|
|
+ return latest_values
|
|
|
|
|
|
- # Derived values
|
|
|
- voltage = float(latest_values.get("batteryVoltage") or 0)
|
|
|
- discharge = float(latest_values.get("batteryDischargeCurrent") or 0)
|
|
|
- charge = float(latest_values.get("batteryChargingCurrent") or 0)
|
|
|
- latest_values["batteryPower"] = (discharge - charge) * voltage
|
|
|
+ def fetch_energy_flow(self, device_id: str) -> dict[str, Any]:
|
|
|
+ """Return the live energy-flow ``fields`` mapping for a device.
|
|
|
|
|
|
- pv_power = float(latest_values.get("pvInputPower") or 0)
|
|
|
- ac_output = float(latest_values.get("acOutputActivePower") or 0)
|
|
|
- feed_in = float(latest_values.get("feedInPower") or 0)
|
|
|
- battery_power = float(latest_values.get("batteryPower") or 0)
|
|
|
+ Fallback source for firmware that never populates the time-series
|
|
|
+ endpoint (issue #7). Returns an empty dict when the endpoint responds
|
|
|
+ without field data, so "no data" and "unsupported" behave identically.
|
|
|
+ """
|
|
|
+ data = self._get(API_ENERGY_FLOW, {"deviceId": device_id, "dataSource": 1})
|
|
|
|
|
|
- latest_values["gridPower"] = max(0.0, ac_output - pv_power + battery_power + feed_in)
|
|
|
- latest_values["loadPower"] = ac_output
|
|
|
+ if data.get("code") not in (0, None, "0"):
|
|
|
+ raise RuntimeError(
|
|
|
+ f"Energy-flow error code={data.get('code')} "
|
|
|
+ f"message={data.get('message') or data.get('msg')}"
|
|
|
+ )
|
|
|
|
|
|
- return latest_values
|
|
|
+ payload = data.get("data") or {}
|
|
|
+ state = payload.get("deviceAttributeState") or {}
|
|
|
+ fields = state.get("fields")
|
|
|
+ if not isinstance(fields, dict):
|
|
|
+ # Tolerate the values being nested directly under data.fields.
|
|
|
+ fields = payload.get("fields")
|
|
|
+ return fields if isinstance(fields, dict) else {}
|
|
|
+
|
|
|
+ @staticmethod
|
|
|
+ def _apply_derived_values(latest_values: dict[str, Any]) -> None:
|
|
|
+ """Compute values the API does not report directly.
|
|
|
+
|
|
|
+ Gap-filling only: when a source such as the energy-flow fallback already
|
|
|
+ supplied a real measurement, it is kept rather than overwritten with an
|
|
|
+ estimate. On the time-series path none of these keys are ever returned
|
|
|
+ by the API, so every one of them is still derived exactly as before.
|
|
|
+ """
|
|
|
+ if latest_values.get("batteryPower") is None:
|
|
|
+ voltage = _coerce_number(latest_values.get("batteryVoltage")) or 0.0
|
|
|
+ discharge = _coerce_number(latest_values.get("batteryDischargeCurrent")) or 0.0
|
|
|
+ charge = _coerce_number(latest_values.get("batteryChargingCurrent")) or 0.0
|
|
|
+ latest_values["batteryPower"] = (discharge - charge) * voltage
|
|
|
+
|
|
|
+ ac_output = _coerce_number(latest_values.get("acOutputActivePower")) or 0.0
|
|
|
+
|
|
|
+ if latest_values.get("loadPower") is None:
|
|
|
+ latest_values["loadPower"] = ac_output
|
|
|
+
|
|
|
+ if latest_values.get("gridPower") is None:
|
|
|
+ pv_power = _coerce_number(latest_values.get("pvInputPower")) or 0.0
|
|
|
+ feed_in = _coerce_number(latest_values.get("feedInPower")) or 0.0
|
|
|
+ battery_power = _coerce_number(latest_values.get("batteryPower")) or 0.0
|
|
|
+ latest_values["gridPower"] = max(
|
|
|
+ 0.0, ac_output - pv_power + battery_power + feed_in
|
|
|
+ )
|
|
|
|
|
|
# ─── Monthly summary (station) ─────────────────────────────────────────────
|
|
|
|