| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392 |
- """Tests for the energy-flow fallback mapping.
- Covers the fallback added for inverter / WiFi-dongle firmware families that
- never populate the historical time-series endpoint, leaving every realtime
- entity "unknown" while the portal shows live data (issue #7).
- The field names and the sample values in ``ISSUE_7_NIGHT_PAYLOAD`` are taken
- verbatim from that report, which was captured at night — hence the zeros.
- The daylight payloads (``ISSUE_7_AC_PV_CHARGING`` / ``ISSUE_7_NOAC_PV_DISCHARGING``)
- are trimmed from hidemichixt-creator's four-state capture set posted
- 2026-09-15, which settled the unit and sign questions the night capture
- could not.
- """
- from __future__ import annotations
- import pytest
- from custom_components.solar_of_things.api import (
- EnergyFlowRuleNotConfiguredError,
- SolarOfThingsAPI,
- TokenExpiredError,
- has_realtime_values,
- map_energy_flow_fields,
- )
- from custom_components.solar_of_things.const import ENERGY_FLOW_UNVERIFIED
- # Exactly the fields reported in issue #7 (UWB1 inverter, night-time reading).
- ISSUE_7_NIGHT_PAYLOAD = {
- "pv1Power": 0,
- "pv2Power": 0,
- "generationPower": 0,
- "batteryPower": 9,
- "positiveTerminalBatteryCurrent": 0.4,
- "negativeTerminalBatteryCurrent": 0,
- "positiveTerminalBatteryVoltage": 26.6,
- "bmsBatteryVoltage": 26.6,
- "batteryPercentage": 100,
- "bmsSOC": 100,
- "load_power": 0,
- "aPhaseOutputVoltage": 222.8,
- "aPhaseOutputFrequency": 50,
- }
- # Trimmed from UPS_AC_PV_BatteryCharging.txt (issue #7, 2026-09-15): AC
- # connected, PV producing, battery charging.
- ISSUE_7_AC_PV_CHARGING = {
- "pv1Power": 234,
- "pv2Power": 0,
- "load_power": 0.614, # kW, per the payload's own "unit" field
- "aPhaseMainsPower": -1100, # W, per the payload's own "unit" field
- "bPhaseMainsPower": 0,
- "cPhaseMainsPower": 0,
- "positiveTerminalBatteryCurrent": -27,
- "negativeTerminalBatteryCurrent": 0,
- "batteryPower": -720,
- "bmsSOC": 54,
- }
- # Trimmed from UPS_NoAC_PV_BatteryDischarging.txt (issue #7, 2026-09-15): AC
- # disconnected, PV producing, battery discharging.
- ISSUE_7_NOAC_PV_DISCHARGING = {
- "pv1Power": 262,
- "pv2Power": 0,
- "load_power": 0.635,
- "aPhaseMainsPower": 0,
- "bPhaseMainsPower": 0,
- "cPhaseMainsPower": 0,
- "positiveTerminalBatteryCurrent": 17.6,
- "negativeTerminalBatteryCurrent": 0,
- "batteryPower": 462,
- "bmsSOC": 54,
- }
- # ─── Pure mapping ──────────────────────────────────────────────────────────────
- def test_issue_7_payload_maps_to_canonical_keys() -> None:
- """The reported payload must populate the previously-unknown sensors."""
- mapped = map_energy_flow_fields(ISSUE_7_NIGHT_PAYLOAD)
- # Units confirmed by a non-zero observed value in the report — publishable.
- assert mapped["pvInputPower"] == 0.0
- assert mapped["batteryVoltage"] == 26.6
- assert mapped["batterySOC"] == 100.0
- assert mapped["batteryPower"] == 9.0
- # Confirmed by the 2026-09-15 daylight captures (see below) — 0 at night
- # is a real reading now, not an unconfirmed guess.
- assert mapped["acOutputActivePower"] == 0.0
- assert mapped["batteryChargingCurrent"] == 0.0
- assert mapped["batteryDischargeCurrent"] == 0.4 # idle trickle, per the report
- # loadPower (camelCase) has no confirmed source — must stay ABSENT rather
- # than publish a possibly-wrong value. See ENERGY_FLOW_UNVERIFIED in const.py.
- assert "loadPower" not in mapped
- def test_ac_output_power_mapped_from_load_power_kw() -> None:
- """load_power is confirmed kW by the payload's own "unit" tag → x1000."""
- mapped = map_energy_flow_fields(ISSUE_7_AC_PV_CHARGING)
- assert mapped["acOutputActivePower"] == 614.0
- def test_grid_import_and_feed_in_split_from_signed_mains_power() -> None:
- """aPhaseMainsPower is confirmed W; negative means importing from mains.
- Sign confirmed by conservation of power: load (614 W) + battery charging
- (720 W) - PV (234 W) = 1100 W, matching |aPhaseMainsPower| exactly.
- """
- mapped = map_energy_flow_fields(ISSUE_7_AC_PV_CHARGING)
- assert mapped["gridPower"] == 1100.0
- assert mapped["feedInPower"] == 0.0 # not exporting while importing
- # No AC connection at all -> the field reads 0, which is a real
- # "no grid" measurement, not a missing one.
- mapped_no_ac = map_energy_flow_fields(ISSUE_7_NOAC_PV_DISCHARGING)
- assert mapped_no_ac["gridPower"] == 0.0
- assert mapped_no_ac["feedInPower"] == 0.0
- def test_battery_charging_and_discharge_current_split_by_sign() -> None:
- """positiveTerminalBatteryCurrent flips sign with charge direction.
- Confirmed across all four states captured for issue #7: negative while
- charging, positive while discharging.
- """
- charging = map_energy_flow_fields(ISSUE_7_AC_PV_CHARGING)
- assert charging["batteryChargingCurrent"] == 27.0
- assert charging["batteryDischargeCurrent"] == 0.0
- discharging = map_energy_flow_fields(ISSUE_7_NOAC_PV_DISCHARGING)
- assert discharging["batteryChargingCurrent"] == 0.0
- assert discharging["batteryDischargeCurrent"] == 17.6
- def test_unverified_fields_are_never_mapped() -> None:
- """No field in ENERGY_FLOW_UNVERIFIED may produce a sensor value.
- A 1000x-wrong power value feeds the HA Energy dashboard and long-term
- statistics, which a later fix cannot un-poison; an inverted charge/discharge
- current is actively misleading. Both are worse than an unknown sensor.
- This is the guard that stops a well-meaning change from re-enabling one of
- these before a confirming capture exists.
- """
- for field in ENERGY_FLOW_UNVERIFIED:
- assert map_energy_flow_fields({field: 500}) == {}, field
- # And as a group, mirroring the shape of a real payload.
- assert map_energy_flow_fields({f: 500 for f in ENERGY_FLOW_UNVERIFIED}) == {}
- def test_multi_string_pv_is_summed_at_face_value() -> None:
- """Per-string PV inputs are reported in W and summed without scaling."""
- mapped = map_energy_flow_fields(
- {"pv1Power": 1200, "pv2Power": 800, "load_power": 1.5}
- )
- assert mapped["pvInputPower"] == 2000.0
- # load_power would need an unconfirmed kW→W conversion, so it stays out.
- assert "loadPower" not in mapped
- def test_generation_power_is_not_used_as_a_pv_fallback() -> None:
- """generationPower is an aggregate in kW and its x1000 is unconfirmed.
- Excluding it means a device reporting ONLY generationPower gets an unknown
- PV sensor rather than one that may be 1000x wrong.
- """
- assert map_energy_flow_fields({"generationPower": 2.4}) == {}
- # A per-string reading is still mapped when one is present.
- assert (
- map_energy_flow_fields({"pv1Power": 500, "generationPower": 2.4})[
- "pvInputPower"
- ]
- == 500.0
- )
- @pytest.mark.parametrize(
- ("raw", "expected"),
- [
- (77, 77.0),
- ("77", 77.0),
- ({"value": 63}, 63.0),
- ([10, 20, 44], 44.0), # latest-wins, as the time-series endpoint returns
- ],
- )
- def test_accepts_the_value_shapes_this_portal_uses(raw, expected) -> None:
- assert map_energy_flow_fields({"bmsSOC": raw})["batterySOC"] == expected
- @pytest.mark.parametrize("raw", [None, True, False, "n/a", "", {}, []])
- def test_rejects_unusable_values_rather_than_publishing_garbage(raw) -> None:
- assert "batterySOC" not in map_energy_flow_fields({"bmsSOC": raw})
- @pytest.mark.parametrize("payload", [None, {}, [1, 2], "text", 0])
- def test_hostile_input_returns_empty_mapping(payload) -> None:
- assert map_energy_flow_fields(payload) == {}
- def test_unknown_firmware_fields_are_ignored() -> None:
- assert map_energy_flow_fields({"someBrandNewKey": 5}) == {}
- # ─── Realtime probe ────────────────────────────────────────────────────────────
- def test_probe_treats_zero_as_a_real_reading() -> None:
- """A device reporting 0 W at night is working — must not trigger fallback."""
- assert has_realtime_values({"pvInputPower": 0}) is True
- @pytest.mark.parametrize(
- "values", [{}, {"pvInputPower": None}, {"loadPower": 5}, None, "text"]
- )
- def test_probe_false_when_no_realtime_key_has_a_value(values) -> None:
- assert has_realtime_values(values) is False
- # ─── fetch_latest_data integration ─────────────────────────────────────────────
- @pytest.fixture
- def api_factory():
- """Build an API instance with stubbed transport, tracking endpoint calls."""
- def _factory(history_fields, flow_fields=None, flow_error=None):
- api = SolarOfThingsAPI(iot_token="test-token")
- api._ensure_token_valid = lambda: None # no network
- calls = {"time_series": 0, "energy_flow": 0}
- def fake_post(path, payload, **kwargs):
- calls["time_series"] += 1
- return {"code": 0, "data": {"payload": {"fields": history_fields}}}
- def fake_get(path, params, **kwargs):
- calls["energy_flow"] += 1
- if flow_error is not None:
- raise flow_error
- return {
- "code": 0,
- "data": {"deviceAttributeState": {"fields": flow_fields or {}}},
- }
- api._post = fake_post
- api._get = fake_get
- return api, calls
- return _factory
- def test_working_device_is_unaffected(api_factory) -> None:
- """Regression guard: values and call pattern must match pre-fallback code."""
- history = {
- "pvInputPower": [100],
- "acOutputActivePower": [1.2],
- "batteryVoltage": [52.0],
- "batteryDischargeCurrent": [2.0],
- "batteryChargingCurrent": [0.0],
- "feedInPower": [0],
- "batterySOC": [90],
- }
- api, calls = api_factory(history, flow_fields={"bmsSOC": 1})
- result = api.fetch_latest_data("device-1")
- assert result["acOutputActivePower"] == 1200.0 # kW → W
- assert result["batteryPower"] == 104.0 # (2.0 - 0.0) * 52.0
- assert result["gridPower"] == 1204.0 # max(0, 1200-100+104+0)
- assert result["loadPower"] == 1200.0
- # The fallback must cost a working install nothing.
- assert calls["energy_flow"] == 0
- def test_hpvinv02_alternate_key_names_are_mapped_to_canonical(api_factory) -> None:
- """Siseli HPVINV02 ("Inverter Top One" gather protocol) reports PV/AC/SOC
- under pvPower / outputActivePower / batteryCapacity instead of the
- documented pvInputPower / acOutputActivePower / batterySOC — these stayed
- "unknown" forever until the alias mapping was added.
- """
- history = {
- "pvPower": [1.5],
- "outputActivePower": [1.1],
- "batteryCapacity": [77],
- "batteryVoltage": [52.0],
- "batteryDischargeCurrent": [2.0],
- "batteryChargingCurrent": [0.0],
- "feedInPower": [0],
- }
- api, calls = api_factory(history, flow_fields={"bmsSOC": 1})
- result = api.fetch_latest_data("device-hpvinv02")
- assert result["pvInputPower"] == 1500.0 # kW → W, via the alias
- assert result["acOutputActivePower"] == 1100.0 # kW → W, via the alias
- assert result["batterySOC"] == 77
- # The alternate keys must not leak into the published values.
- assert "pvPower" not in result
- assert "outputActivePower" not in result
- assert "batteryCapacity" not in result
- # Derived values still come from the shared _apply_derived_values path.
- assert result["batteryPower"] == 104.0 # (2.0 - 0.0) * 52.0
- assert result["loadPower"] == 1100.0
- assert calls["energy_flow"] == 0
- def test_documented_keys_win_when_a_device_reports_both(api_factory) -> None:
- """A device that already uses the documented key names must be unaffected
- by the alias — the canonical value always wins, the alias is discarded,
- and (critically) pvInputPower is NOT kW->W converted on this path: it's
- already W for every device this integration supported before HPVINV02,
- and converting it unconditionally regressed test_working_device_is_unaffected.
- """
- history = {
- "pvInputPower": [2.0],
- "pvPower": [999],
- "acOutputActivePower": [1.0],
- "batterySOC": [55],
- "batteryCapacity": [10],
- }
- api, _ = api_factory(history, flow_fields={})
- result = api.fetch_latest_data("device-both-keys")
- assert result["pvInputPower"] == 2.0
- assert result["batterySOC"] == 55
- def test_fallback_populates_sensors_when_time_series_is_empty(api_factory) -> None:
- api, calls = api_factory({}, flow_fields=ISSUE_7_NIGHT_PAYLOAD)
- result = api.fetch_latest_data("device-2")
- assert calls["energy_flow"] == 1
- assert result["batteryVoltage"] == 26.6
- assert result["batterySOC"] == 100.0
- assert result["batteryPower"] == 9.0
- def test_measured_battery_power_is_not_overwritten_by_the_estimate(api_factory) -> None:
- """The flow endpoint reports batteryPower directly; keep it.
- The terminal currents are no longer mapped from flow data (direction
- unconfirmed), so no voltage x current estimate can be derived from this
- payload at all — but the no-clobber precedence must still hold for devices
- that get their currents from the time-series path.
- """
- api, _ = api_factory({}, flow_fields=ISSUE_7_NIGHT_PAYLOAD)
- assert api.fetch_latest_data("device-3")["batteryPower"] == 9.0
- def test_time_series_values_win_over_the_fallback(api_factory) -> None:
- api, calls = api_factory({"batterySOC": [42]}, flow_fields={"bmsSOC": 99})
- result = api.fetch_latest_data("device-4")
- assert result["batterySOC"] == 42
- assert calls["energy_flow"] == 0
- def test_flow_endpoint_failure_degrades_quietly(api_factory) -> None:
- """An unsupported endpoint must not fail the whole coordinator update."""
- api, _ = api_factory({}, flow_error=RuntimeError("404 not supported"))
- result = api.fetch_latest_data("device-5")
- assert isinstance(result, dict)
- assert result["loadPower"] == 0.0
- def test_token_expiry_propagates_for_reauth(api_factory) -> None:
- """TokenExpiredError must reach the coordinator so re-auth can start."""
- api, _ = api_factory({}, flow_error=TokenExpiredError("expired"))
- with pytest.raises(TokenExpiredError):
- api.fetch_latest_data("device-6")
- def test_energy_flow_rule_not_configured_logs_a_warning(api_factory, caplog) -> None:
- """Issue #21: this failure mode looked identical to "no data" — no
- sensors AND no warning — because it fell into the same silent DEBUG-level
- except clause as an unsupported/404 endpoint. It must be loud by default,
- since the fix (configuring an energy-flow rule on the portal) is on the
- user/installer's side, not something a future field mapping can resolve.
- """
- api, _ = api_factory(
- {}, flow_error=EnergyFlowRuleNotConfiguredError("code=70132 message=Energy flow rule not exists")
- )
- with caplog.at_level("WARNING"):
- result = api.fetch_latest_data("device-8")
- assert isinstance(result, dict) # still degrades quietly, not a raised error
- assert any(record.levelname == "WARNING" for record in caplog.records)
- assert "energy-flow rule" in caplog.text.lower()
- def test_unknown_firmware_logs_field_names_for_reporting(api_factory, caplog) -> None:
- api, _ = api_factory({}, flow_fields={"someBrandNewKey": 5, "another": 7})
- api.fetch_latest_data("device-7")
- assert "another" in caplog.text and "someBrandNewKey" in caplog.text
|